Vickery-Simms Venturi Flow Tube

Return to Main Equipment Page

Back to Process Equipment Index Page

[Click to enlarge] [Click to enlarge] [Click to enlarge] [Click to enlarge]
Vickery-Simms Venturi Flow Tube (Pic 1)
Vickery-Simms Venturi Flow Tube (Pic 2)
Vickery-Simms Venturi Flow Tube (Pic 3)
Vickery-Simms Venturi Flow Tube (Pic 4)
[Click to enlarge] [Click to enlarge]
Vickery-Simms Venturi Flow Tube (Pic 5)
Vickery-Simms Venturi Flow Tube

Vickery-Simms Flow Venturi (15.9731" Bore)

**New Surplus**

Operating Conditions:

Meter Tube I.D. (D): 25.25"
Meter Type: (Dry or Hg): Dry
Differential @ max.flow (Hm): 10.0000 Inches Water
Max. Flow (Qm or Wm): 22,000 ACFM
Normal Flow: 17,000 ACFM
Flowing Temperature: 300 deg. F
Flowing Material: Flue Gas
Specific Gravity or Molecular Weight: 29.5000
Compressibility @ base condition: 1.0000 at flow condition: 1.0000
Specific Weight @ base condition: 0.0777 at flow condition: 0.0549
Operating Vescosity, centipoises: 0.0210
Base temperature: 60 deg. F.
Atmospheric Pressure (PSIA): 14.70
Meter tap location: Venturi
Static pressure tap location: Upstream
Throat material: 304 Stainless steel
Body & Flanged end material: Carbon Steel
Reynolds Number @ normal flow: 667329.66

Calculations:

(1) Wm (lbs/hr): 72456.57
(2) D x D: 637.5625
(3) Fa: 1.0043
(4) Fm: 1.0000
(5) Fc: 1.0040
(6) Y: 0.9904
(7) Sq. Root (sp.wt.): 0.2343
(8) Sq. Root (Hm): 3.1623
(9) 358.9x(2) thru (8): 169306.53090
S = (1) / (9): 0.4280
BETA = 0.6326
Bore = 15.9735"
Flow Rate (ACFM): 6957.011 x Sq. Root (diff. In. water)

SML RESOURCES INTERNATIONAL
FOR INQUIRIES CONTACT
ROY LEADER